Solvent Distillers DYnamic serie

 

In the units of the DYnamic series, 30 - 60 - 120 litres capacity, a rotating scraper having adjustable metallic blades keeps the content to be treated constantly in movement allowing maximum extraction of the residues to stick to the boiler’s wall and bottom.

An automatic drying cycle will allow the residues to be extracted in solid or powder state.

Through a simple distillation process, they separate the contaminants (resins, polymers, pigments, paints, oils, etc.) from the original solvent.

The boiling of the solvent is accomplished by a peripheral heating jacket filled with diathermic oil, heated by an electrical element.

The vapours are then conveyed to a condenser cooled by air or water. The condensed solvent is collected in a tank, for its reuse. A rotating scraper having adjustable metallic blades keeps the content to be treated constantly in movement allowing maximum extraction of solvent while avoiding the residues to stick to the boiler’s wall and bottom.

An automatic drying cycle will allow the residues to be extracted in solid or powder state.

The DYnamic serie can be connected to a vacuum unit, suitable for high boiling solvents or for those flammable ones which have a boiling point close to the flash point. The vacuum module can be equipped with an air operated vacuum pump or an electrical vacuum according at wish.

 

Scarico dei residui del processo di distillazione
con impianti della serie Dynmic

Model

Loading capacity (litres)
Processing
time (hours)
Dryness cycle time (adjustable)
Protection
Flammable solvents
Not flammable solvents
Dimensions (cm)
Weight (kg)
DiQ 30 Ax 30 3.30 - 4.30 0 - 5 hours Atex II2G IIA T3 to T2 85 x 105 x h116 175
DiQ 60 Ax 60 3.30 - 4.30 0 - 5 hours Atex II2G IIA T3 to T2 69 x 110 x h160 260
DQ120 Ax 120 3.30 - 4.30 0 - 5 hours Atex II2G IIA T3 to T2 151 x 114 x h206 473
DQ 60 Ax 60 3.30 - 4.30 0 - 5 hours Atex II2G IIA T3 to T2 90 x 130 x h165 420
DQ 120 Ax 120 3.30 - 4.30 0 - 5 hours Atex II2G IIA T3 to T2 118 x 152 x h203 630
230/400 Volts - 50/60 Hz 
* In the Countries where it is allowed by the existing norms and respecting the particular conditions of installation and use
FORMECO reserves itself the right to bring modifications without advising