Solvent Distillers DIstatic serie
| The units of the DIstatic serie, with capacity of 7 - 12 -
15 - 30 - 60 - 120 - 160 - 230 litres are distillers which allow the recycling and the
re-use of degreasing and washing solvents. Through a simple distillation process, they
separate the contaminants (resins, polymers, pigments, paints, oils, etc.) from the
original solvent. The boiling of the solvent is accomplished by a peripheral heating jacket filled with diathermic oil, heated by an electrical element. The vapours are then convoyed to a condenser cooled by air or water. The condensed solvent is collected in a tank, for its reuse. The contaminants remain as a residue inside a disposable bag named "Rec-Bag" ; in case of liquid residue, by tilting the unit itself. The distilled solvent characteristics are not altered by the distillation process, which can be carried on repeatedly.The DIstatic serie can be connected to a vacuum unit, suitable for high boiling solvents or for those flammable ones which have a close boiling point and flash point. The vacuum module can be equipped with an air operated vacuum pump or an electrical vacuum according to the need. |
| 15 litres plant | 30 litres plant | 120 litres plant | ||
|
|
![]() |
||
| Model | Loading capacity (litres) | Processing time (hours) | Protection |
|
|
|
|
| Si 7 A (Ax) | 7 | 2.30 - 3.30 | AD-T IP44 | * | | 55 x 65 x h115 | 40 |
| Si 12 A (Ax) | 12 | 3.30 - 4.30 | AD-T IP44 | * | | 55 x 65 x h130 | 54 |
| Di 15 A (Ax) | 15 | 3.30 - 4.30 | Atex II2G IIA T3 to T2 | | | 63 x 73 x h145 | 67 |
| Si 30 A (Ax) | 30 | 3.30 - 4.30 | AD-T IP44 | * | | 60 x 99 x h116 | 110 |
| Di 30 A (Ax) | 30 | 3.30 - 4.30 | Atex II2G IIA T3 to T2 | | | 60 x 99 x h116 | 142 |
| Si 60 A (Ax) | 60 | 3.30 - 4.30 | AD-T IP44 | * | | 69 x 110 x h160 | 180 |
| Di 60 A (Ax) | 60 | 3.30 - 4.30 | AD-T IP44 | | | 69 x 110 x h160 | 212 |
| Si 120 A (Ax) | 120 | 3.30 - 4.30 | AD-T IP44 | * | | 151 x 114 x h206 | 361 |
| Di 120 A (Ax) | 120 | 3.30 - 4.30 | AD-T IP44 | | | 151 x 114 x h206 | 393 |
| Si 160 A (Ax) | 160 | 3.30 - 4.30 | AD-T IP44 | * | | 151 x 120 x h210 | 433 |
| Di 160 A (Ax) | 160 | 3.30 - 4.30 | AD-T IP44 | | | 151 x 120 x h210 | 465 |
| S 60 A (Ax) | 60 | 3.30 - 4.30 | Atex II2G IIA T3 to T2 | * | | 90 x 130 x h165 | 308 |
| D 60 A (Ax) | 60 | 3.30 - 4.30 | Atex II2G IIA T3 to T2 | | | 90 x 130 x h165 | 340 |
| S 120 Ax | 120 | 3.30 - 4.30 | Atex II2G IIA T3 to T2 | * | | 118 x 152 x h203 | 502 |
| D 120 Ax | 120 | 3.30 - 4.30 | Atex II2G IIA T3 to T2 | | | 118 x 152 x h203 | 534 |
| S 230 Ax | 230 | 3.30 - 4.30 | Atex II3G IIA T3 to T2 | * | | 150 x 180 x h245 | 968 |
| D 230 Ax | 230 | 3.30 - 4.30 | Atex II3G IIA T3 to T2 | | | 150 x 180 x h245 | 1000 |
| 230/400 Volt - 50/60 Hz - Built according norms CEE 89/392 - 91/368 - CEI 64-2 - EN 50 014/015/018 |
* In the Countries where it is allowed by the
existing norms and respecting the particular conditions of installation and use |
![]()